1.
Europace ; 23(3): 395-399, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33197266

RESUMO

AIMS: To guarantee uninterrupted function of the subcutaneous implantable cardioverter-defibrillator (S-ICD), the pulse generator needs to be surgically replaced before the battery is depleted. The risks related to this replacement substantially impact long-term outcome for S-ICD recipients, as the majority will undergo one or several of these procedures in their lifetime. We aim to describe the procedural characteristics of the replacement procedure and to provide an insight in the complications associated with these replacements. METHODS AND RESULTS: In this retrospective analysis, data from replacement procedures and follow-up visits were collected from all patients who underwent elective S-ICD generator replacement in our tertiary centre from June 2014 until November 2019. Original device position was assessed using the PRAETORIAN score. Complications were defined as those requiring surgical intervention, systemic antibiotic treatment, or device extraction. Seventy-two patients were included, with a median follow-up of 1.9 years (IQR 0.6-3.3 years) after replacement. Battery depletion occurred after 5.9 ± 0.7 years. The pulse generator was repositioned in patients with a PRAETORIAN score ≥90 to minimize the defibrillation threshold. Although there was an increase in impedance compared to the implant procedure, first shock conversion rate during defibrillation testing was 91.4% with a success rate of 100% after multiple attempts. Two patients developed a complication after, respectively, 9 and 21 months, resulting in a complication rate of 1.4% per year. CONCLUSION: With a median follow-up of 1.9 years, this study shows a low complication rate after S-ICD replacement, with a first shock conversion rate of 91.4%.


Assuntos
Desfibriladores Implantáveis , Desfibriladores Implantáveis/efeitos adversos , Impedância Elétrica , Humanos , Estudos Retrospectivos , Resultado do Tratamento
2.
N Engl J Med ; 383(6): 526-536, 2020 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-32757521

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) was designed to avoid complications related to the transvenous ICD lead by using an entirely extrathoracic placement. Evidence comparing these systems has been based primarily on observational studies. METHODS: We conducted a noninferiority trial in which patients with an indication for an ICD but no indication for pacing were assigned to receive a subcutaneous ICD or transvenous ICD. The primary end point was the composite of device-related complications and inappropriate shocks; the noninferiority margin for the upper boundary of the 95% confidence interval for the hazard ratio (subcutaneous ICD vs. transvenous ICD) was 1.45. A superiority analysis was prespecified if noninferiority was established. Secondary end points included death and appropriate shocks. RESULTS: A total of 849 patients (426 in the subcutaneous ICD group and 423 in the transvenous ICD group) were included in the analyses. At a median follow-up of 49.1 months, a primary end-point event occurred in 68 patients in the subcutaneous ICD group and in 68 patients in the transvenous ICD group (48-month Kaplan-Meier estimated cumulative incidence, 15.1% and 15.7%, respectively; hazard ratio, 0.99; 95% confidence interval [CI], 0.71 to 1.39; P = 0.01 for noninferiority; P = 0.95 for superiority). Device-related complications occurred in 31 patients in the subcutaneous ICD group and in 44 in the transvenous ICD group (hazard ratio, 0.69; 95% CI, 0.44 to 1.09); inappropriate shocks occurred in 41 and 29 patients, respectively (hazard ratio, 1.43; 95% CI, 0.89 to 2.30). Death occurred in 83 patients in the subcutaneous ICD group and in 68 in the transvenous ICD group (hazard ratio, 1.23; 95% CI, 0.89 to 1.70); appropriate shocks occurred in 83 and 57 patients, respectively (hazard ratio, 1.52; 95% CI, 1.08 to 2.12). CONCLUSIONS: In patients with an indication for an ICD but no indication for pacing, the subcutaneous ICD was noninferior to the transvenous ICD with respect to device-related complications and inappropriate shocks. (Funded by Boston Scientific; PRAETORIAN ClinicalTrials.gov number, NCT01296022.).


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Idoso , Cardiomiopatias/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Eletrodos Implantados/efeitos adversos , Falha de Equipamento , Feminino , Seguimentos , Cardiopatias/terapia , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Desenho de Prótese
3.
JAMA Cardiol ; 2(6): 678-683, 2017 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-28241248

RESUMO

Importance: Adults late after total correction of tetralogy of Fallot (TOF) are at risk for major complications. Cardiovascular magnetic resonance (CMR) imaging is recommended to quantify right ventricular (RV) and left ventricular (LV) function. However, a commonly used risk model by Khairy et al requires invasive investigations and lacks CMR imaging to identify high-risk patients. Objective: To implement CMR imaging in noninvasive risk stratification to predict major adverse clinical outcomes. Design, Setting, and Participants: This multicenter study included 575 adult patients with TOF (4.083 patient-years at risk) from a prospective nationwide registry in whom CMR was performed. This study involved 5 tertiary referral centers with a specialized adult congenital heart disease unit. Multivariable Cox hazards regression analysis was performed to determine factors associated with the primary end point. The CMR variables were combined with the noninvasive components of the Khairy et al risk model, and the C statistic of the final noninvasive risk model was determined using bootstrap sampling. The data analysis was conducted from January to December 2016. Main Outcomes and Measures: The composite primary outcome was defined as all-cause mortality or ventricular arrhythmia, defined as aborted cardiac arrest or documented ventricular fibrillation and ventricular tachycardia (lasting ≥30 seconds or recurrent symptomatic). Results: Of the 575 patients with TOF, 57% were male, and the mean (SD) age was 31 (11) years. During a mean (SD) follow-up of 7.1 (3.5) years, the primary composite end point occurred in 35 patients, including all-cause mortality in 13 patients. Mean (SD) RV ejection fraction (EF) was 44% (10%), and mean (SD) LV EF was 53% (8%). There was a correlation between RV EF and LV EF (R, 0.36; 95% CI, 0.29-0.44; P < .001). Optimal thresholds for ventricular function (RV EF <30%: hazard ratio, 3.90; 95% CI, 1.84-8.26; P < .001 and LV EF <45%: hazard ratio, 3.23; 95% CI, 1.57-6.65; P = .001) were independently predictive in multivariable analysis. Both thresholds were included in a point-based noninvasive risk model (C statistic, 0.75; 95% CI, 0.63-0.85) and combined with the noninvasive components of the Khairy et al risk model. Conclusions and Relevance: In patients with repaired TOF, biventricular dysfunction on CMR imaging was associated with major adverse clinical outcomes. The quantified thresholds (RV EF <30% and LV EF <45%) may be implemented in noninvasive risk stratification.


Assuntos
Volume Sistólico , Tetralogia de Fallot/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Mortalidade , Análise Multivariada , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Tetralogia de Fallot/cirurgia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...